2. Equipped with a steady flow ring device, the characteristic curve has no hump and no danger of surge.
3. The installation angle of the blade can be adjusted, and the fan condition can be adjusted at any time according to the changes in mine production.
4. Compact s" />

国产做a爱片久久毛片A片古代,丰满少妇人妻hd高清大乳,纯肉无遮挡h肉动漫在线观看3d,在线看片免费人成视久网

Language: Chinese line English

Mine fan

  • Industrial mine main fan
  • Industrial mine main fan
Industrial mine main fanIndustrial mine main fan

Industrial mine main fan

  • Product description: 1, the use of twisted airfoil blades, high aerodynamic efficiency, energy saving effect is extremely significant.
    2. Equipped with a steady flow ring device, the characteristic curve has no hump
  • INQUIRY

Structure


The mine ventilator is mainly composed of a current collector, a first-stage main cylinder, a second-stage main cylinder and a covered muffler. Its transmission method is direct motor transmission, which is more compact, safe and convenient, and durable. The voltage level is (380/660)V or (660/1140)V, and the user can select the connection mode according to the power supply voltage requirements. The body and structural parts of the coal mine counter-rotating ventilator are welded by steel plates, and the shell is covered with silencing measures to reduce the noise of the ventilator. The whole machine is simple and compact in structure, strong and durable, safe in use and convenient in maintenance.


Product Parameters

No.

Motor Power

(KW)

Air Volume

(m3/s)

Full Pressure

(Pa)

Minimum Duct Diameter

(mm)

Air Supply Distance

(m)

JK58-1No3 1.5 0.9-1.4 928-575 300 80
JK58-1No3.5 3 1.5-2.4 1263-752 350 150
JK58-1No4 5.5 2.2-3.5 1648-1020 400 200
JK58-1No4.5 11 3.1-5.0 2093-1295 450 300
JK58-2No4 11 2.2-3.5 2923-1811 400 400
JK55-2No4.5 11 3.0-5.2 2276-1275 450 300
JK55-1No5 11 4.2-6.6 1726-1324 450 200
JK56-1No3.15 2.2 1.4-2.1 853-588 300 80
JK56-1No4 4 2.1-3.4 1275-981 400 150

Installation

1. Before use, strictly check that the radial clearance between the wind wheel and the shell is 1.5 ‰ ~ 3.5 ‰ of the diameter of the impeller, and it is not less than 1.00mm, and the clearance around is uniform.

2. The rotation direction of the impeller must be consistent with the direction shown by the arrow on the casing

3. Ventilators must be managed and operated by special personnel

4. The installation of ventilator must conform to the relevant provisions of "Coal Mine Safety Regulations"

5. For ventilators that have been transported for a long time or put on hold for a long time, the cold insulation resistance of the stator of the motor must be measured before use (the insulation resistance shall not be less than 50 megohms, and drying treatment shall be carried out if it does not meet the requirements). The required power supply can be connected only after passing the inspection. The trial operation will take about ten minutes. If there is no abnormal sound, it can be put into operation.

6. The peeling length of the connection of the motor lead-in wire joint is not more than 1.5 ㎜

7. When the ventilator is used underground in a coal mine, the power supply inlet must adopt a U-shaped non-flame-delayed sheathed rubber cable with a cable specification of 3 ×X +1 ×X

8. The adhesive tape ram shall be as long as possible and the maximum diameter allowed by the roadway section, and each section shall be as long as possible, and shall be laid as straight as possible. The pipe wall shall not be wrinkled, and the direction shall be slowly changed at the turning point to reduce the resistance loss of the pipe and ensure the air supply distance. Generally, the diameter of all ram shall not be less than the diameter of the fan outlet.

Scan the qr codeClose
the qr code