2. Ventilation and air diversion of boilers and industrial furnaces.
3. Cooling and ventilation in air conditioning equipment and household appliances.
" />

国产做a爱片久久毛片A片古代,丰满少妇人妻hd高清大乳,纯肉无遮挡h肉动漫在线观看3d,在线看片免费人成视久网

Language: Chinese line English

Support

What is a boiler induced draft fan

Boiler induced draft fan is a common mechanical prop in factories and coal mines. It belongs to a kind of centrifugal exhaust fan. So, many people will ask, what is the boiler induced draft fan? What are its effects?

1. What is the induced draft fan of the boiler

The boiler induced draft fan is a machine that uses the mechanical energy typed by the motor to raise the gas pressure and send the gas in parallel. The key is to pump out the flue gas of the boiler and maintain the negative pressure of the boiler. After the flue gas passes through the air preheater for electric dust removal, it will enter the induced draft fan. The induced draft fan uses mechanical energy to increase the gas pressure, sends the flue gas into the desulfurization system, and finally disconnects into the chimney. Because the induced draft fan must bear the strong corrosion of high-temperature gas such as SO2, HCl, etc., and friction with dust must be carried out, therefore, the induced draft fan in front of the dust collector has a very large dust composition, and a good anti-corrosion coating must be used to carry out maintenance. What are the key components of industrial axial flow and centrifugal fans?

2. How to install boiler induced draft fan

First of all, before installing the boiler induced draft fan, it is necessary to check whether there are sundries in the boiler induced draft fan. If there are sundries, they should be eliminated immediately. In addition, check whether there are gaps or scratches in the impeller. It is necessary to immediately carry out adjustment in time to prevent the application efficiency of the equipment from being endangered during installation. Second, the thickness of the roadbed for installing boiler induced draft fans should be a concrete floor of not less than 30cm. Again, the boiler induced draft fan shall be put into trial operation after installation. The air valve shall be turned off before starting, so that the fan shall be started at full load. The air valve can be opened slowly after normal rotating speed. During the operation of the equipment, the current shall be strictly monitored and shall not exceed the rated value. After 20 minutes of operation, the bearing box shall be checked to see if the temperature rise is normal.

CATEGORIES

CONTACT US

Contact: Mr Wu

Phone: 400-670-7798

Tel: 0533-6060097

Email: zbxinhuafan@163.com sales@xhblower.com

Add: The southern suburbs of the town industrial park Zhoucun Zibo Shandong

Scan the qr codeClose
the qr code