Summary
1, 6-46-11 type dust centrifugal fan is suitable for discharging the mixture of air, such as wood debris, fiber and dust.
2, the fan model is expressed by 6-46-11, which:
(1) 6 said fan at the highest efficiency (max) of the total pressure coefficient by 10 after the integer.
(2) 46 said fan at the highest efficiency (max) is the specific speed of integer.
(3) in which the first digit number (1) represents the single suction fan, and the number of the number of 1 represents the design sequence number () number of 11.
3, No. 4 for the following fan, in the range of working efficiency and the pressure decline in its value shall comply with the following provisions:
(1) No. 4 is not lower than the curve on the specified value 95%.
(2) No. 3 is not lower than the curve on the specified value 90%.
structure
4, No. 3-6 meters for motor direct (A type) and the pulley (C type) two transmission mode. No. 8-12 meters pulley (C type) and coupling (D type) two transmission mode.
5. The fan has 6 blades which are bent forward, the front plate and the rear plate and the cast iron wheel shell. Impeller dynamic balance test, smooth operation.
6, the spindle adopts high quality carbon steel manufacturing.
7, for the maintenance of convenient installation, no 3-12 fan casing, are integral.
8, the ventilator can be made into left and right rotary rotary two styles, fixed on the air inlet side and outlet position of each rotary direction, no 3-6 into 6 different positions, no 8-12 can be made into 3 different positions.
6-46-11 centrifugal fan complete set of delivery scope
A
C
D
Centrifugal fan
A
A
A
Motor
A
A
A
Fan bolt
Four
No. 3-6
No. 8-12
Eight
Four
Eight
Motor bolt
One
A set
One
Four guide rails for motor
One
A set
One
Belt pulley two triangle belt
One
A set
One
Installation, use and maintenance instructions
1, before installation should be checked in detail whether the fan parts are damaged, to be properly repaired before installation.
2, before installation should be checked in detail whether the connection part of the phenomenon of loosening, impeller and air inlet gap size, rotating part and fixed part whether there is a collision phenomenon.
3, the chassis and bearing bearings should be consistent with the nature of the foundation, may not be forced to avoid deformation.
4, the motor shaft and the fan shaft should be carefully corrected concentric vibration, so as not to run.
5, after the installation is completed, carefully check whether the bolts are tightened around, and try running.
6, fan flow Q and total pressure of H, spindle speed and shaft power of n N four have a fixed relationship shown as the following formula.
When the motor capacity does not change, not change the spindle speed, spindle speed increases, the motor had burned the dangerous load.
7, the fan motor refers to the specific conditions and mechanical loss and its reserves, is not required to open the air outlet power, such as the entrance or exit with pipeline or not by the external resistance of idling, the motor is in danger of being burned. The safety valve should be added to the outlet or inlet pipe of the fan, the valve will be opened slowly to achieve the specified operating conditions, and pay attention to whether the motor exceeds the specified current.
8, rolling bearing using yellow glycerine lubrication, oil should not be too much, you can in the rolling bearing center, in maintenance shall not be mixed with sand, iron inside.
9, the bearing temperature in normal operation shall not exceed 65 degrees, otherwise it should be checked and repaired.
10, pay attention to the impeller or belt wheel rotation is balanced, the connection is loose, whether the body vibration, should be checked and corrected at any time.
11, V type tape should be often uniformly strained and the ambient temperature should not be too high, and avoid contact with oily tape.
12, with the coupling drive should pay attention to the motor and spindle concentricity, in order to avoid vibration or cause bearing heating and so on.
13, the ventilator should be special maintenance, regular maintenance, repair time varies with the use of the length, the selection should be in accordance with the actual conditions.
6-46-11 performance and selection table
Machine No.
№
|
transmission
mode
|
speed
r/min
|
Serial number
|
flow
m3/h
|
Total pressure
Pa
|
Motor
|
Model
|
power KW
|
2
|
A
|
2800
|
1
2
3
4
5
6
7
8
|
400
420
460
500
540
600
640
700
|
667
647
598
589
569
520
491
441
|
JW08A-2
|
0.25
|
JW09B-2
|
0.4
|
3
|
A
|
2900
|
1
2
3
4
5
6
7
8
|
1183
1427
1671
1915
2159
2403
2647
2891
|
1451
1461
1451
1432
1393
1344
1285
1206
|
Y100L-2
|
3
|
4
|
A
|
1450
|
1
2
3
4
5
6
7
8
|
1404
1692
1980
2268
2556
2844
3132
3420
|
677
686
677
667
657
628
598
569
|
Y100L1-4
|
2.2
|
5
|
A
|
1450
|
1
2
3
4
5
6
7
8
|
2733
3294
3855
4416
4977
5538
6099
6660
|
1118
1128
1118
1098
1079
1030
990
932
|
Y132S-4
|
5.5
|
6
|
A
|
1450
|
1
2
3
4
5
6
7
8
|
4725
5696
6667
7638
8609
9580
10551
11522
|
1608
1628
1608
1587
1549
1491
1422
1344
|
Y160M-4
|
11
|
6
|
A
|
960
|
1
2
3
4
5
6
7
8
|
3130
3775
4420
5065
5710
6355
7000
7645
|
706
706
706
696
677
657
628
598
|
Y132S-6
|
3
|